1. Category Name Reference Data Address Remarks Firmware Firmware Version 400001 0000H Data Cell Voltage 400002 0001H Cell Temperture 400003 0002H Cell Resistance 400004 0003H Command Reset 400012 000BH Modifys the value in the register to 0xF0F0 , the module will perform a reset. Test Cell Resistance 400013 000CH Modifys the value in the register to 0xF0F0 , the module will perform a resistance test, and the IR value in the register 400004 will be updated after 30 seconds. The value in this register will be 0x0000 after a IR test done. Parameters IR index 400016 000DH The default value is 10000. Module Address 400015 000EH The default address is 1. IR Mode 400017 0010H 0= IR test mode 0, takes 10 seconds for one IR test, 1= IR test mode 1 takes 30 seconds for one IR test. The default value is 1 Baut Rate 400022 0015H The default value is 9600BPS.